In the process of using hydrogen detectors, many typical problems may be encountered and their coping strategies are as follows:
1. The detector does not display or works poorly
● The root cause of the problem: power supply problems, including poor contact of the power cord, adapter damage; Or internal circuit failure.
● Solution: First, confirm that the power cable connection is stable, and try to replace the adapter to ensure a smooth power supply. If the power supply is fine and the device still does not respond, it may mean that there is a problem inside the circuit and you need to consult a professional technician to repair or replace the device.
2. Detector false alarm
Cause analysis: external interference, such as electromagnetic wave interference, vibration; Sensor aging/damage; Or other gases like hydrogen are present in the environment.
● Countermeasures: Check and remove nearby sources of electromagnetic interference and vibration. Frequent false alarms indicate that the sensor may be aged or damaged and needs to be replaced in a more timely manner. At the same time, look for and reduce possible gas interference in the environment, and consider adjusting the detector sensitivity or using a more selective detector.
3. The detector does not alarm or delays the alarm
● Cause of failure: sensitivity setting is too low; Sensors are contaminated/blocked; Hydrogen leakage is below the alarm threshold.
● Solution steps: Review and adjust the sensitivity setting according to demand. Clean the sensor and replace it in case of serious obstruction. For small leaks, it is recommended to use precision detection tools, and consider adding detectors or optimizing the installation layout to improve monitoring efficiency.
4. Readings are unstable
● Cause: severe fluctuation of ambient temperature and humidity; Sensor performance fluctuates.
● Treatment: Ensure that the detector is in the recommended temperature and humidity environment, and install a protective shell or take other protective measures if necessary. If the readings are unstable due to fluctuations in sensor performance, the sensor needs to be replaced or repaired by a professional.
Summary: In order to ensure the effective operation of hydrogen detectors, regular maintenance and calibration should be performed. In the face of any fault, first according to the above guidance self-diagnosis and treatment, such as complex problems, timely recourse to professional and technical personnel for professional maintenance.