What are the common failures of on-board hydrogen sensors, and what is the solution?

来源:Drksir 时间:2024-09-18 10:02:02

        Common failures of on-board hydrogen sensors include:

        

Drksir Vehicle hydrogen sensor

        1. Abnormal signal output: The sensor's internal components may be aging or damaged, resulting in unstable or incorrect output signals.

        2. Slow response: the sensor response time is prolonged, and it cannot quickly reflect the change of hydrogen concentration.

        3. Zero drift: After the sensor is used for a long time, the reference point (zero point) changes, resulting in deviation of the measurement results.

        4. Decreased sensitivity: Long-term exposure to high concentrations of hydrogen or harsh environments may reduce the sensitivity of the sensor.

        5. Circuit fault: power supply problem or internal circuit damage, resulting in the sensor can not work normally.

        For the above faults, the following solutions can be taken:

        1. If the signal output is abnormal: check whether the cable connecting to the sensor is damaged and try to replace the sensor or calibrate it. If the problem persists, you may need to replace the circuit board or the sensor itself.

        2. Slow response: Check whether the sensor needs to be cleaned or replaced, and whether there is too much dust or pollutants in the surrounding environment. Sometimes, recalibrating the sensor can also solve the response speed problem.

        3. Zero drift: zero calibration is carried out regularly to ensure that the reference value of the sensor is accurate. If the drift is severe, a professional may be required to correct or replace the sensor.

        4. Sensitivity loss: Sensitivity recovery test, such as cleaning gas by purging or using calibration gas. If it cannot be restored, consider replacing the sensor.

        5. Circuit fault: First check the power connection of the sensor to ensure normal power supply. Use a multimeter to check that all parts of the circuit, including the cell voltage, are within the normal range (for example, about 2.3V). Repair or replace damaged power supply or circuit parts.

        Note: Before performing any repair or calibration operations, ensure that you have read and understood the sensor's manual and safety guidelines, and if necessary, have professional technicians handle it to ensure safety and effectiveness.

        


关注公众号

了解更多传感器知识

公众号:德克西尔

传感器产品二维码

加微信

购买传感器产品

微信号:Drksir-13515810281

相关内容推荐
What are the installation methods and precautions for fixed hydrogen sensors, and what are the commo

What are the installation methods and precautions for fixed hydrogen sensors, and what are the commo

        The installation method and precautions of the fixed hydrogen sensor are as follows:        First, installation method:        1. Location selection: According to the point where hydrogen may leak, select a location that is easy to detect and will not be interfered with by other gases.        2. Fixed installation: Use a suitable mounting bracket or bracket to ensure that the sensor is stable and avoid vibration.        3. Wiring and debugging: Wiring correctly according to the wiring diagram provided by the manufacturer, including power cord, signal output line, etc., and initial calibration and debugging.        4. Environment adaptation: Ensure that the installation environment meets the requirements of the sensor operating temperature and humidity. Take measures to prevent dust and water if necessary.        Second. Precautions:        1. Ensure that no obstacles block the detection range of the sensor.        2. Check the working status of the sensor regularly and clean the surface of the sensor.        3. Ensure that the installation environment is properly grounded according to the electrical safety regulations.        4. Avoid installation in direct sunlight or in an environment with rapid temperature changes.        The common faults and solutions of fixed hydrogen sensors are as follows:        1. Signal drift or instability: Calibrate the sensor regularly, check and clean the sensor, and replace the sensor if necessary.        2. If no signal is generated, check whether the power cable and signal cable are connected properly and whether the power supply is stable.        3. Slow response: Check whether the sensor needs to be cleaned or replaced, and confirm whether the detection environment meets the conditions for the use of the sensor.        4. False alarm: Check whether there is other gas interference, adjust the sensor sensitivity or replace a more specific sensor.        
2024.09.13
在线客服

业务咨询

技术咨询

售后服务

PC端自动化二维码
135-1581-0281 (即时通话) 459879587 (在线询价) 135-1581-0281 (长按复制)
扫码加微信