How to use the handheld hydrogen leak detector, how to set the alarm concentration value?

来源:Drksir 时间:2024-09-17 10:38:59

        The basic steps to use a handheld hydrogen leak detector are as follows:

Portable hydrogen concentration detector

        1. Pre-check and boot: First check the appearance of the instrument for damage, ensure that the battery is sufficient, and then boot according to the instructions.

        2. Calibration: Calibrate before each use to ensure the accuracy of measurement results. This usually involves calibration with a standard sample of hydrogen at a known concentration.

        3. Setting: According to the need to detect the environment and requirements, set the appropriate alarm threshold and unit (such as ppm or %LEL).

        4. Detection: Put the instrument near or into the suspected leak area, move slowly, and observe the instrument reading and alarm.

        5. Record and analysis: record the test results, if there is excessive, it is necessary to record the exceeded location and concentration in detail, further analyze the cause and take measures.

        6. Shutdown and maintenance: After use, correctly turn off the instrument according to the instructions, and carry out necessary cleaning and maintenance.

        Setting the alarm concentration value of the handheld hydrogen leak detector should be based on the following points:

        1. Safety standards: refer to industry safety standards and regulations, such as workplace safety limits, usually the lower explosive limit (LEL) of hydrogen is 4%, and the alarm value can be considered at 1%LEL or lower when the initial setting.

        2. Application environment: Depending on the risk level of the use scenario, such as in high-risk areas such as chemical plants or hydrogen energy stations, more stringent alarm thresholds may be required.

        3. Instrument characteristics: According to the performance and accuracy of the handheld hydrogen leak detector, as well as its recommended alarm setting range, select the appropriate alarm point.

        4. Practical requirements: Considering the purpose of detection, if it is preventive maintenance, a lower alarm value may be set to detect potential problems early; If it is an emergency response, a high alarm value may be required for a faster response.

        In short, setting the alarm concentration value should take into account the safety, environment, equipment performance and actual needs, and if necessary, consult professionals or follow the manufacturer's recommended value.

        


关注公众号

了解更多传感器知识

公众号:德克西尔

传感器产品二维码

加微信

购买传感器产品

微信号:Drksir-13515810281

相关内容推荐
What are the installation methods and precautions for fixed hydrogen sensors, and what are the commo

What are the installation methods and precautions for fixed hydrogen sensors, and what are the commo

        The installation method and precautions of the fixed hydrogen sensor are as follows:        First, installation method:        1. Location selection: According to the point where hydrogen may leak, select a location that is easy to detect and will not be interfered with by other gases.        2. Fixed installation: Use a suitable mounting bracket or bracket to ensure that the sensor is stable and avoid vibration.        3. Wiring and debugging: Wiring correctly according to the wiring diagram provided by the manufacturer, including power cord, signal output line, etc., and initial calibration and debugging.        4. Environment adaptation: Ensure that the installation environment meets the requirements of the sensor operating temperature and humidity. Take measures to prevent dust and water if necessary.        Second. Precautions:        1. Ensure that no obstacles block the detection range of the sensor.        2. Check the working status of the sensor regularly and clean the surface of the sensor.        3. Ensure that the installation environment is properly grounded according to the electrical safety regulations.        4. Avoid installation in direct sunlight or in an environment with rapid temperature changes.        The common faults and solutions of fixed hydrogen sensors are as follows:        1. Signal drift or instability: Calibrate the sensor regularly, check and clean the sensor, and replace the sensor if necessary.        2. If no signal is generated, check whether the power cable and signal cable are connected properly and whether the power supply is stable.        3. Slow response: Check whether the sensor needs to be cleaned or replaced, and confirm whether the detection environment meets the conditions for the use of the sensor.        4. False alarm: Check whether there is other gas interference, adjust the sensor sensitivity or replace a more specific sensor.        
2024.09.13
在线客服

业务咨询

技术咨询

售后服务

PC端自动化二维码
135-1581-0281 (即时通话) 459879587 (在线询价) 135-1581-0281 (长按复制)
扫码加微信